Use this method to set number of retries that must fail, out of the number specified for the Retries parameter, for a service to be marked as DOWN. For example, if the Retries parameter is set to 10 and the Failure Retries parameter is set to 6, out of the ten probes sent, at least six probes must fail if the service is to be marked as DOWN. The default value of 0 means that all the retries must fail if the service is to be marked as DOWN.

Syntax



Parameters

monitorname

Name of the monitor.
This is mandatory parameter.

type

Type of monitor that you want to create.
This is mandatory parameter.
Possible Values : PING, TCP, HTTP, TCP-ECV, HTTP-ECV, UDP-ECV, DNS, FTP, LDNS-PING, LDNS-TCP, LDNS-DNS, RADIUS, USER, HTTP-INLINE, SIP-UDP, SIP-TCP, LOAD, FTP-EXTENDED, SMTP, SNMP, NNTP, MYSQL, MYSQL-ECV, MSSQL-ECV, ORACLE-ECV, LDAP, POP3, CITRIX-XML-SERVICE, CITRIX-WEB-INTERFACE, DNS-TCP, RTSP, ARP, CITRIX-AG, CITRIX-AAC-LOGINPAGE, CITRIX-AAC-LAS, CITRIX-XD-DDC, ND6, CITRIX-WI-EXTENDED, DIAMETER, RADIUS_ACCOUNTING, STOREFRONT, APPC, SMPP, CITRIX-XNC-ECV, CITRIX-XDM, CITRIX-STA-SERVICE, CITRIX-STA-SERVICE-NHOP, MQTT, HTTP2, DTLS, QUIC, KAFKA-AUTODISCOVER.

failureretries

Number of retries that must fail, out of the number specified for the Retries parameter, for a service to be marked as DOWN. For example, if the Retries parameter is set to 10 and the Failure Retries parameter is set to 6, out of the ten probes sent, at least six probes must fail if the service is to be marked as DOWN. The default value of 0 means that all the retries must fail if the service is to be marked as DOWN.
Maximum value = 32.

Return Value